Search results for " power measurement"
showing 10 items of 15 documents
Electronic Energy Meter Based on a Tunnel Magnetoresistive Effect (TMR) Current Sensor
2017
In the present work, the design and microfabrication of a tunneling magnetoresistance (TMR) electrical current sensor is presented. After its physical and electrical characterization, a wattmeter is developed to determine the active power delivered to a load from the AC 50/60 Hz mains line. Experimental results are shown up to 1000 W of power load. A relative uncertainty of less than 1.5% with resistive load and less than 1% with capacitive load was obtained. The described application is an example of how TMR sensing technology can play a relevant role in the management and control of electrical energy.
A PC-based wattmeter for accurate measurements in sinusoidal and distorted conditions: Setup and experimental characterization
2012
This paper presents the development of a high-accuracy sampling wattmeter, which can be employed with both sinusoidal and distorted input signals. The proposed personal computer (PC)-based system is a simple, portable, and low-cost solution because it is based on two commercial data acquisition boards connected to a common PC. Owing to this solution, the voltage is sensed directly, avoiding expensive voltage dividers, while the current is sensed by means of a noninductive current shunt. Commercial software is also used for data processing and implementation of the virtual instrument. The setup of the PC-based wattmeter is described, with a detailed description of the correction strategy of …
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
2011
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.
IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment
2018
The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.
Dynamic Lighting Strategies with Load Modulation Purposes to Reduce Peak Electrical Demand
2018
This paper proposes a study about the feasibility to modulate the indoor artificial lighting, taking into account both achievable energy savings and comfort conditions, in order to reduce lighting electric loads. In particular, it focuses on the possibility, on one hand, to decrease the luminous flux and, on the other hand, to change the Correlated Colour Temperature (CCT), in order to decrease the absorbed power. Moreover, the impact of daylight-linked control systems was considered. Finally, the possibility to combine the different technical solutions was analysed. The paper proposes the definition of daily scheduling referred to lighting energy management, in order to modulate the maximu…
A virtual instrument for the measurement of IEEE Std 1459-2000 power quantities
2006
In this paper, the authors present a PC-based instrument for the measurement of electrical-power quantities defined in IEEE Std. 1459. The instrument is based on a time-domain technique for the detection of the fundamental and harmonic components of voltages and currents. The time-domain strategy was originally developed by the authors for three-phase, three-wire systems. In that paper, the strategy had been extended to both three-phase, four-wire and single-phase systems. Simulation tests were carried out to assess the uncertainty contribution of the proposed strategy in the absence of the measurement transducers. Moreover, the accuracy of the PC-based instrument with its transducers was e…
Riferibilità dei contatori statici di energia reattiva in presenza di armoniche. Evoluzione normativa e prove sperimentali
2013
A PC-based wattmeter for high accuracy power measurements
2010
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.
LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids
2016
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…
A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000
2010
In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…